After 3 years of follow-up, no functional or esthetic difficulties with the implants and restorations were noted. “
“Patients
PCI-32765 research buy with acquired defects or congenital malformations of the palate exhibit disturbances in speech, including hypernasality, nasal emission, and decreased intelligibility of speech. Maxillofacial prosthetic treatment can reestablish the palatopharyngeal integrity to provide the potential for acceptable speech. This article describes a case series of patients with palatopharyngeal disorders and their treatment approaches. “
“The most frequently encountered problem with fixed detachable dental prostheses is loosening or fracture of the prosthetic screws. Other problems include wear, separation or fracture of the resin teeth from the metal/acrylic prosthesis, chipping or fracture of porcelain from the metal/ceramic or zirconia/ceramic prosthesis, and fracture of the framework in some free-end prostheses. For this type of prosthesis it is necessary to place the implants in a position that enables occlusal or lingual access so as not to impair the esthetics. This clinical report describes the
restoration of a patient with complete fixed detachable maxillary and mandibular prostheses made of monolithic zirconia with angled dental implants with buccal access. The prostheses were esthetically pleasing, selleck and no clinical complications have been reported Nintedanib (BIBF 1120) after 2 years. “
“Purpose: This study analyzed baseline and post-fatigue reverse-torque values (RTVs) for a specific brand control abutment relative to a third party compatible abutment.
The purpose of this study was to compare the abutments’ fatigue resistance to simulated function, using RTVs as an indication of residual preload at the implant/abutment interface. Materials and Methods: Forty Straumann tissue-level implants were mounted in resin and divided into four groups (n = 10). Forty abutments were seated, 20 control and 20 third-party abutments, according to manufacturer guidelines. Ten abutments from each manufacturer were evaluated for RTV without fatigue loading, using a calibrated digital torque gauge to provide a baseline RTVs. Fatigue loading was carried out on the remaining ten specimens from each manufacturer according to ISO 14801 guidelines. A moving-magnet linear motor was used to load one specimen per sequence, alternating from 10 to 200 N at 15 Hz for 5×106 cycles. RTV was recorded post-fatigue loading. The results were subjected to two-sample t-testing and two-way ANOVA. Scanning electron microphotography was carried out on three specimens from both manufacturers at baseline and post-fatigue cycling to visualize thread geometry and the abutment/implant interface. Results: The data indicated that mean post-fatigue RTV observed for the control group was significantly higher than the third-party group (RTV 42.65 ± 6.70 N vs. 36.25 ± 2.63 N, p= 0.0161).